Dual-Channel Loop Detector DoorKing Part Number This “Self-tuning” loop detector is designed to be used with DoorKing vehicular gate operators ONLY and control two individual loops (including 2 series wired reversing loops configuration). The loop detector plugs into loop detector ports on the gate operator control board. DOORKING DIRECT BURIAL LOOP ***FREE SHIPPING*** Highest quality prefabricated ground loop installed before pouring new concrete, asphalt, gravel or pavers driveway. Description: Used for installations under concrete, asphalt, pavers, or gravel roads. Unlike loops wrapped through PVC, The DK Loops do not have an. Refer to the Loop Information Manual located at www.doorway.ru for information on installing in-ground loops. Glasgow Avenue Inglewood, California U.S.A.
Use this manual for the Model operators with circuit board Rev V or higher ONLY. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligatio n of DoorKing, Inc. to notify any persons of any such revisions or changes. (DoorKing 3-Button station ONLY) Exit Loop Logic Output (DoorKing Loop Detectors ONLY) 3-Button Full Open (DoorKing 3-Button station ONLY) Dry Relay Contact Full Open Partial Open Standard Reverse or Stop Not Used Low Voltage Common Full Open 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 † When gate is closed, this input will fully open gate. component that controls the loop system. DoorKing offers loop detectors (Models , ) that plug directly into the gate operator control board, eliminating the wire harness and wiring connections other than the loop lead-in wires. These detector boards have a terminal strip where the loop lead-in wire connects. There are also various other.
(DoorKing 3-Button station ONLY) Exit Loop Logic Output (DoorKing Loop Detectors ONLY) 3-Button Full Open (DoorKing 3-Button station ONLY) Dry Relay Contact Full Open Partial Open Standard Reverse or Stop Not Used Low Voltage Common Full Open 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 † When gate is closed, this input will fully open gate. Loop area (Sq. Ft.) - Multiply loop width by loop length. Note: The number of turns should be increased by 1 turn if lead-in wire or cable length is ft or greater. Loop Area in Square Feet Number of Turns Required 6 - 12 12 - 60 60 - 6 4 3 2 (Side 1 + Side 2 + Side 3 + Side 4) Number of Turns2 = Inductance 2. component that controls the loop system. DoorKing offers loop detectors (Models , ) that plug directly into the gate operator control board, eliminating the wire harness and wiring connections other than the loop lead-in wires. These detector boards have a terminal strip where the loop lead-in wire connects. There are also various other.
0コメント